A clearer understanding. A more practical approach.
EMFPracticalAssess your room ↗
Home / Compare

COMPARE

The differences that matter.

Compare emf meters by what they measure, how they record, and what they cannot tell you.

← EMF meters buying criteria

Select products to compare

RF meters

Multi-field meters

Dirty electricity meters

Documented specifications for EMF meters
Compare capabilities Gigahertz Solutions HF35C RF Meter Gigahertz Solutions HF38B RF Meter Gigahertz Solutions HF59B RF Meter Gigahertz Solutions HFE35C RF Meter Kit Gigahertz Solutions HFE59B RF Meter Kit Gigahertz Solutions HFEW35C RF Meter Kit Gigahertz Solutions HFW59D RF Meter Safe and Sound Pro II FM5 Path 5G Monitor TriField TF2 Safe and Sound EM3 EPE Conseil Cemprotec 34 EMF Meter Dirty Electricity Line EMI Monitor
Photo Gigahertz Solutions HF35C RF Meter Gigahertz Solutions HF38B RF Meter Gigahertz Solutions HF59B RF Meter Gigahertz Solutions HFE35C RF Meter Kit Gigahertz Solutions HFE59B RF Meter Kit Gigahertz Solutions HFEW35C RF Meter Kit Gigahertz Solutions HFW59D RF Meter Safe and Sound Pro II FM5 Path 5G Monitor TriField TF2 Safe and Sound EM3 EPE Conseil Cemprotec 34 EMF Meter Dirty Electricity Line EMI Monitor
Field types — — — — — — — RF only RF only RF, AC electric, AC magnetic AC electric (1-axis), AC magnetic (3-axis), body voltage RF, AC electric, AC magnetic Line-conducted EMI ("dirty electricity") — not RF, electric or magnetic fields
Frequency range 800 MHz - 2.7 GHz 700 MHz - 3.3 GHz 700 MHz - 3.3 GHz (extendable to 27MHz with UBB27 antenna, sold separately) 27 MHz - 2.7 GHz (omnidirectional); 800MHz-2.7GHz (directional) 27 MHz - 3.3 GHz (omnidirectional); 700MHz-3.3GHz (directional) — 2.4 GHz - 10 GHz, incl. 8.5-9.5GHz radar band — — — — — 10 kHz–10 MHz
Combined frequency range — — — — — 27 MHz - 6 GHz (via 2 meters) — — — — — — —
RF coverage — — — — — — — 200 MHz–8 GHz detection 1 MHz–10 GHz (Basic and Complete); 24–32 GHz mmWave module (Complete only) 20 MHz–6 GHz — 1 MHz–10 GHz —
Recording — — — — — — — Peak, maximum and average display Peak/max signal on LED display; directional antenna and audio tone for source-finding Manual recording; peak hold Manual reading; body-voltage measurement via included cable — —
Accuracy (manufacturer) +/-6dB linearity deviation +/-6dB linearity deviation — +/-6dB linearity deviation — — +/-4.5dB linearity deviation — — — — — —
Antenna — — Directional Logarithmic Periodic (LogPer), 45deg — — — Directional Logarithmic Periodic (LogPer), 45deg — — — — — —
Antennas — — — Omnidirectional UBB27 (360deg) + Directional LogPer (45deg) Omnidirectional UBB27 (360deg) + Directional LogPer (45deg) — — — — — — — —
Includes — — — — — HFE35C meter, HFW35C meter, 3 antennas, carrying case — — — — — — —
Line noise range — — — — — — — — — — — — 0.1–1999.9 mVp-p AC (differential); accuracy ±8% at 20 kHz–2 MHz, within a factor of 2 from 10 kHz–10 MHz
Sensitivity — — — — — — — — Low-frequency module: 1 µW/m² to 100,000+ µW/m². High-frequency module: 30 µW/m² to 100,000+ µW/m² — — — —
Low-frequency coverage — — — — — — — — — — — 10 Hz–5 kHz (electric and magnetic) —
Detection modes Peak, Average; analogue + pulsed-digital Peak Hold, Peak, Average; analogue + pulsed-digital Peak Hold, Peak, Average; analogue + pulsed-digital Peak, Average; analogue + pulsed-digital Peak Hold, Peak, Average; analogue + pulsed-digital Peak, Average; audio tone signal ID on both meters Peak, Average, Peak Hold; audio tone signal ID — — — — — —
Sensitivity (manufacturer) — ~10x the HF35C; ~100x the entry-level HF32D — — — — — — — — — — —
Measuring ranges — — Coarse / Medium / Fine; DG20 attenuator optional — Coarse / Medium / Fine, plus DG20 attenuator included — — — — — — — —
Voltage reading — — — — — — — — — — — — 85–250 VAC (±1 VAC); operates on 85–300 VAC, 50/60 Hz
Power 9V alkaline battery included, ~6-7 hrs continuous use 9V alkaline battery included, ~6-7 hrs continuous use Rechargeable NiMH battery + charger included 9V alkaline battery included Rechargeable NiMH battery + charger included 9V alkaline battery included Rechargeable NiMH battery + charger included — 9V battery; approx. 50 mA on the low-frequency module, approx. 200 mA on the high-frequency module — — — —
Display — — — — — — — — — — — — 4-digit yellow/blue two-colour OLED; audio tone scales with EMI intensity
Suggested reading guide — — — — — — — — — — — — Below 25 mV: low. 25–50 mV: marginal. Above 50 mV: high (per manufacturer)
Starting price $382.11 $546.15 $1,275.18 $1,034.61 $2,252.69 $1,554.68 $1,274.87 $399.00 £299.99 £159.99 $649.00 £199.99 £169.99
Available from Safe Living Technologies Safe Living Technologies Safe Living Technologies Safe Living Technologies Safe Living Technologies Safe Living Technologies Safe Living Technologies Safe Living Technologies (retailer) EMF Protection UK EMF Protection UK, Safe Living Technologies (retailer) Safe Living Technologies (retailer) EMF Protection UK EMF Protection UK
Limitations Accuracy/linearity deviation is manufacturer-specified at +/-6dB. Maximum display resolution requires the external DG20 attenuator (sold separately) to read very strong signals. Accuracy/linearity deviation is manufacturer-specified at +/-6dB. Maximum display resolution requires the external DG20 attenuator (sold separately) to read very strong signals. This is the directional-antenna-only version of the HFE59B kit -- if you want the omnidirectional UBB27 antenna and the DG20 attenuator included rather than as separate purchases, compare pricing against the HFE59B kit directly. Accuracy/linearity deviation is manufacturer-specified at +/-6dB. Runs on a single 9V alkaline battery (included). This is a professional/technician-grade instrument, priced and specified accordingly -- most home users will get adequate coverage from a lower-tier meter (e.g. HF35C or HFE35C) unless you specifically need the omnidirectional antenna, the built-in attenuator, or data-logging output. This is two separate meters in one case, not a single wideband instrument -- you switch between them depending on which frequency range you're checking. See the individual HFE35C and HFW35C listings for each meter's own accuracy spec. Accuracy/linearity deviation is manufacturer-specified at +/-4.5dB -- typical for this class of professional RF analyzer, not a defect, but worth knowing when comparing readings across meters. A separate preamplifier (HV20_2400 G10) is needed for the lowest-signal sensitivity range and is sold separately. Specified ±6 dB response covers 400 MHz–7.2 GHz. Does not measure low-frequency electric or magnetic fields. Basic and Complete cover different frequency ranges — confirm which configuration you are ordering. Not returnable once satisfactory, only if faulty. The mmWave module draws roughly 4x the current of the low-frequency module, so battery life drops noticeably when it is in use. RF and electric-field sensing are single-axis. Check orientation and the manual. RF and wireless signals are not covered — pair with a dedicated RF meter (such as the Safe and Sound Pro II) for wireless-frequency questions. A rechargeable version is sold at the same price; confirm which you are ordering. The Safe and Sound EM3 is a professional 3-in-1 EMF meter designed for accurate measurement of low-level AC magnetic and electric fields. Suitable for home and professional use, it offers wide frequency coverage, high sensitivity and third-party calibrated specifications. Measures line-conducted electrical interference only — it does not measure RF, electric or magnetic fields, so it is not a substitute for a general EMF meter. No battery required; needs a free wall outlet to use.
Product page View & order → View & order → View & order → View & order → View & order → View & order → View & order → View & order → View & order → View & order → View & order → View & order → View & order →
Specification comparison, not a hands-on review. Current prices, shipping and returns must be confirmed with the provider.